Cooling Hole Drilling for Generator Rotor Windings
Large generator rotors have cooling holes drilled through the winding slots to allow hydrogen or air to circulate and remove heat. The holes are typically 8-15mm diameter, drilled lengthwise through the rotor forging. In my experience, a blocked cooling hole is one of the most common causes of generator rotor failure, so the quality of these holes matters more than most people realize. Rotor Forging Materials and Cooling Hole Layout The rotor material is usually a high-strength steel forging like 25CrMo4 or similar. The rotor can be 6-10 meters long with cooling holes running the full length. The position tolerance for the holes is typically within 0.5mm of the design coordinate. ...